Our dry cabinets & dry storage space options deliver a small (<0.5%), controlled degree of moisture. Moisture absorbing components including digital components, circuit panels, nano fibers, contact lenses, lab examples as well as other vulnerable components are kept dry and free of water ingress. The dehumidification to less than .5% RH is eligible Low Humidity Cabinets not only for limitless safe storage, but additionally indicates they can securely remove moisture, therefore resetting flooring life without having oxidation, even at background temperatures.

Options for that storage space of digital elements and compositions to avoid two of the largest defect triggers: Oxidation and Diffusion.

The storage space of digital elements and compositions is challenging, and more and more so due to two problems.

As a result of fast changes in packaging design and materials, a lot of companies wind up compelled to buy extra quantities of elements to be able to shield up against the effect of component obsolescence on their last product designs. As a result produces a concern of long term stock storage space

Product lifecycles have become very brief with new designs being released faster than in the past. Nevertheless, numerous manufacturers, such as vehicle suppliers, must ensure the availability of replacement components such as PCBs for approximately 10 years. This case also necessitates the progress buy and prolonged storage space of elements and components. Additional complicating the problem is that most components cannot be kept for more than 10 years without having special dealing with methods.

Element micro-cracking caused by the absorption and rapid release of dampness. The biggest danger posed is moisture. It is the reason behind two of the most popular problem triggers: Oxidation and Diffusion.

As a result of surface oxidation, components and PCB’s can are afflicted by reduced solderablity, which frequently brings about total malfunction. Diffusion of vapour and noxious substances inside the internal structure from the elements or PCB’s may result in long-term disintegration of conductor pathways and solitude layers. Each dangers can be avoided by proper dealing with and dried out storage space.

The oxidation procedure – contact corrosion

Within an ultra-dried out environment there is no rust. For corrosion to take place, two demands has to be met: there should be a way of oxidation along with a watering solution, which works as being an electrolyte. The oxygen in the air forms the method of oxidation, the vapour (humidity) the electrolyte. The critical restrict at which oxidation with o2 happens is situated in accordance with the steel or alloy at between 40 to 70 % RH. Because of this a lot more than 8 grams of vapour per m³ has to be present.

Remedy 1: Dried out Storage Cupboard

The absolute moisture in Electronic Dry Cabinets lies with a temperature of 20 °C and <2%RH with less than 0.35 g/m³. Under these conditions no cathode reaction is present and no oxidation can take place.

Solution 2: Dampness Buffer Bags

In humidity protection bags loaded under vacuum using a relaxation pressure of ca. 6 mbar there will be between .1 and .06 g vapour per m³. When the hand bags are loaded with nitrogen, neither of the two a way of oxidation, nor an electrolyte can be found, and oxidation is extremely hard.

The Diffusion process

The vapour in the atmosphere diffuses into hygroscopic components. The reason for this is the so called vapour pressure – what this means is the partial pressure in the vapour which is present in the air. The larger the vapour stress, the quicker the ingredients or PCB’s soak up humidity and with this the permissible processing time decreases.

All elements classes 2a to 5a as outlined by the classification of IPC/JEDEC J-STD020D absorb no moisture having a vapour stress of < 2.82. At this particular degree they may be stored and refined indefinitely.

ProDry Storage Cupboards sustain more than twenty four hours normally a vapour stress of < 0.95 mbar reliably and effectively protecting from moisture diffusion. For Moisture Control Cabinets of over 5 many years, a mix of the 2 systems anmtvj recommended. The storage in humidity protection hand bags with nitrogen present inside a simple dried out storage space cupboard with 5 % RH.